Dynamometer Test Result
           
36 Volts
  Torque Ouput Current (Amps) RPM Power Input Efficiency
  2.26 N//M 23.6 3116 738W (989HP) 86.8%
  2.825 N/M 29.1 2950 873W (1.170HP) 83.3%
  3.39 N/M 34.7 2825 1003W (1.345HP) 80.3%
           
           
48 Volts
  Torque Ouput Current (Amps) RPM Power Input Efficiency
  2.26 N//M 22.2 3730 883W (1.184HP) 82.5%
  2.825 N/M 27.2 3450 1021W (1.369HP) 78.2%
  3.39 N/M 32.4 3245 1153W (1.545HP) 74.1%